SIGNAL GENERATOR MODEL
Overview

The VSM Signal Generator is supplied as standard with both ProSPICE Professional. It models a simple audio functional generator with the following features:
- Square, saw-tooth, triangle and sine output waveforms.
- Output frequency range from 0-12MHz in 8 ranges
- Output amplitude from 0-12V in 4 ranges.
- Amplitude and frequency modulation inputs.
Using the Signal Generator
To set up a simple audio signal source
- Pick the SIGNAL GENERATOR object by selecting the
Meter icon in ISIS and then selecting the Signal Generator from the
Object Selector. Place one on the schematic and wire its outputs into
the rest of the circuit. In most circumstances (i.e. unless the circuit
you are driving requires a balance input source), you will want to
ground the -ve terminal of the generator. You most easily achieve
this using a ground terminal. The amplitude and frequency modulation
inputs can be left unconnected unless you are using these features.

- Start an interactive simulation by pressing the play button on the Animation Control Panel. The signal generator popup window should appear.
- Set the frequency range dial to a value suitable
for your application. The range values indicate the frequency that
is generated when the center vernier control is set at 1.

- Set the amplitude range dial to a value suitable
for your application. The range values indicate the amplitude that
is generated when the level vernier control is set at 1. The amplitude
values represent peak output levels.

- Push the waveform button until the LED next to
the appropriate waveform icon is lit.

Using AM & FM Modulation Inputs
The signal generator model supports both amplitude and frequency modulation of the output waveform. Both the amplitude and frequency inputs have the following features:
- The gain of the modulation input in terms of Hz/V or V/V is set by the Frequency Range and Amplitude Range controls respectively.
- The modulation input voltages are clamped at +/- 12V.
- The modulation inputs have infinite input impedance.
- The voltage at the modulation input is added to the setting of the appropriate vernier control before being multiplied by the range setting to determine the instantaneous output frequency of amplitude.
For example, if the frequency range is set at 1KHz, and the frequency vernier is set at 2.0, then a frequency modulation level of 2V will give an output frequency of 4kHz.